Liqua-Tech LPM-200 LP
Gas Flowmeter
Internationally recognized for superior flowmeter replacement
parts, Liqua-Tech now offers the Model LPM-200 LP Gas
liquid flowmeter. Designed for tank trucks and bulk plants,
the LPM-200 offers the widest flow range, (20-110 gpm)
available in a meter of this type. In addition, the LPM-200
utilizes all ductile iron housing castings for unequaled
reliability, durability and many years of low maintenance,
truck use.
The LPM-200 is completely compatible with the Neptune
Type 4D 2" flowmeter; both its external dimensions
and its internal parts.
Liqua-Tech's new patented Trac-Bearing Measuring Chamber
comes standard providing superior performance, accuracy
and reliability.
At the heart of the model LPM-200 flowmeter is the superior
Liqua-Tech Measuring Chamber with Liqua-Tech's original,
hard coated piston with special dense metal oxide finish
and hardened, steel bearing shaft field proven in tens
of thousands of installations internationally. In addition
the Liqua-Tech measuring chamber is now available with
the new, patented Trac-Bearing for improved accuracy,
reliability and lower maintenance.
Veeder-Root register (printing or counter only) for field
proven reliability and lowest operating torque.
Exclusive Liqua-Tech Gear calibration plate (VRA-205,
VRA, 201) which offers Neptune style change gears for
calibration with the Veeder-Root register.
Specifications:
- Rate of flow: 20 to 110 gpm (80 to 400 lpm)
maximum.
- Working Pressure: 350 psi (24 bar) maximum
(24.6 kg/cm2)
- Direction of Flow: Standard assembly has
inlet at left rear, outlet to right. Many other combinations
are possible to suit the installation.
- Connections: Inlet check valve and outlet
differential pressure valve has 2" female pipe
threads. Each is flanged to flowmeter, permitting
easy installation.
- Register & Calibration: Veeder-Root model
7890 with special Liqua-Tech VRA-205 or VRA-201 Gear
calibration plate
- Units of Measure: Calibration is in US gallons,
Imperial gallons or liters.
- Reset Wheel Capacity: 9.999.9 gallons (99999
liters).
- Printing Wheel Capacity: Model 7890 - 9,999.9
gallons (99999 liters)
- Totalizer Capacities: 9,999,999 gallons (99,999,999
liters).
- Temperature Compensator: Compensates to 60F
(15C)
- Range: -10 F to 125 F (-23 C to 52 C)
- Weight: Temperature Compensated, Direct Reading
Reset Counter with Zero start Printer and Totalizer
(Veeder-Root Register Model 7890) 205 lbs. (93 kgs.)
|
|
|
|
|